This article is about SAES-O-202 which is about Plant Security Fencing and download SAES-O-202 PDF for Engineers, supervisors and project managers, QCs, QC Supervisors. This is saudi aramco standards of Safety and Security Engineering based on international codes and standards and useful for Engineering Security knowledge to get job as engineers, QC Supervisors and QC managers, Engineering managers and technicians.
SAES-O-202 PDF Download
SAES-O-202Plant Security Fencing
SAES-O-202 is a Saudi Aramco Engineering Standard that outlines the mandatory requirements for the design and installation of security perimeter fencing at Saudi Aramco industrial facilities. This standard applies to facilities classified under SAES-O-201, Section 4.2, which refers to the classification of facilities based on the Security Directive SEC-01.
When implementing the requirements of SAES-O-202, Security Directive SEC-02 issued by the High Commission for Industrial Security (HCIS), under the Ministry of Interior, Government of Saudi Arabia, must be followed. The specific details and additional requirements related to security perimeter fencing can be found in SEC-02.
It is essential to refer to both SAES-O-202 and SEC-02 to ensure compliance with the mandatory requirements for the design and installation of security perimeter fencing at Saudi Aramco industrial facilities.
Industry Codes and Standards for SAES-O-202
For the design and installation of security perimeter fencing as specified in SAES-O-202, the following industry codes and standards are referenced:
- American Society for Testing and Materials (ASTM)
- ASTM F2656-07: Test Method for Vehicle Crash Testing of Perimeter Barriers
- ASTM F567: Standard Practice for Installation of Chain-Link Fence
These ASTM standards provide guidelines and procedures for testing the effectiveness of perimeter barriers against vehicle crashes and offer best practices for the installation of chain-link fences.
When implementing SAES-O-202, compliance with these ASTM standards ensures that the security perimeter fencing at Saudi Aramco industrial facilities meets the required quality and performance standards.
General Requirements
The general requirements for the design and installation of security perimeter fencing, as outlined in SAES-O-202, include the following:
4.1: The design and installation of security perimeter fencing should be based on the security classification of the facility, as specified in SAES-O-201.
4.2: All areas where SAES-O-202 required elements are installed must be graded and cleared of vegetation. The clear zones should have a 2% slope, away from the facility, to ensure proper water drainage.
4.3: Facilities with a security classification of Class 1 require a Category 1 fencing system. The specific requirements for this system can be found in Section 4.3 of SEC-02. It consists of the following components:
- Outermost Clear Zone: At least 15 meters wide, containing an asphalted patrol road (4.6 meters wide) followed by a clear zone.
- Crash Rated Barrier: A certified barrier meeting or exceeding the requirements of ASTM F2656 M50-P1. The clear zone associated with this barrier should extend 800 meters-15 meters inside the anti-vehicle barrier.
- Anti-Personnel Fence: A 3-meter high chain-link fence with reinforced poles and three rolls of concertina (one on the top, one on the top front, and one on the bottom front).
- Intrusion Sensors: Installed in a 7.5-meter area on the inside of the anti-personnel fence, incorporating at least two types of sensing technologies and cameras as specified in SAES-O-205.
- Lighting System: Installed after the intrusion sensors, at a maximum distance of 3 meters behind the cameras, in compliance with SAES-O-204.
- Internal Interface Layer: Includes an internal clear zone (at least 5 meters wide) followed by a 4.6-meter wide asphalted inner patrol road. A standard Type-III fence (Saudi Aramco Drawing AB-036677-001), as specified in SAES-M-006, should be installed in the clear zone.
These requirements ensure the proper design and installation of security perimeter fencing based on the facility’s security classification and comply with the relevant provisions of SEC-02.
FAQs about SAES-O-202 PDF Download
Q1: What is SAES-O-202?
A1: SAES-O-202 is a Saudi Aramco Engineering Standard that provides guidelines for the design and installation of security perimeter fencing at company facilities.
Q2: What determines the design and installation of security perimeter fencing?
A2: The design and installation of security perimeter fencing should be based on the security classification of the facility, as specified in SAES-O-201.
Q3: What are the clear zone requirements for areas with security perimeter fencing?
A3: All areas where SAES-O-202 required elements are installed must be graded and cleared of vegetation. The clear zones should have a 2% slope, away from the facility, to ensure proper water drainage.
Q4: What are the requirements for Category 1 fencing systems?
A4: Facilities with a security classification of Class 1 require a Category 1 fencing system. The specific requirements for this system can be found in Section 4.3 of SEC-02. It includes components such as an outermost clear zone, crash-rated barrier, anti-personnel fence, intrusion sensors, lighting system, and internal interface layer.
Q5: What is the purpose of the crash-rated barrier in a Category 1 fencing system?
A5: The crash-rated barrier is a certified barrier designed to meet or exceed the requirements of ASTM F2656 M50-P1. It provides protection against vehicle intrusion and has a specific clear zone associated with it.
Q6: What are the requirements for the anti-personnel fence in a Category 1 fencing system?
A6: The anti-personnel fence should be a 3-meter high chain-link fence with reinforced poles and three rolls of concertina. It is an important component for preventing unauthorized access.
Q7: What is the purpose of the intrusion sensors and cameras in a Category 1 fencing system?
A7: Intrusion sensors and cameras are installed in a designated area on the inside of the anti-personnel fence. They provide detection capabilities and surveillance to enhance the security of the facility.
Q8: What is the internal interface layer in the security perimeter fencing?
A8: The internal interface layer consists of an internal clear zone followed by an asphalted inner patrol road. A standard Type-III fence, as specified in SAES-M-006, should be installed in the clear zone.
Q9: Are there specific lighting requirements for the security perimeter fencing?
A9: Yes, a lighting system should be installed after the intrusion sensors, at a maximum distance of 3 meters behind the cameras, in compliance with SAES-O-204.
Q10: Where can I find more information about the requirements for security perimeter fencing?
A10: For more detailed information and specific requirements, it is recommended to refer to the full SAES-O-202 standard and the relevant provisions of Security Directive SEC-02.
Read Also:
SAES-O-201 PDF Download – Application of Security Directives
Pingback: SAES-O-204 PDF Download - Plant Security Lighting - PDFYAR - Engineering Notes, Documents & Lectures