This article is about SAES-T-938 which is about Telecommunications: Outside Plant System Design and download SAES-T-938 PDF for telecommunication and electrical engineers, supervisors and project managers, telecom QCs, telecom QC Supervisors. This is saudi aramco standards of Telecommunication Engineering based on international codes and standards and useful for telecom and electronics engineering knowledge to get job as engineers, QC Supervisors and QC managers, Engineering managers and technicians.

SAES-T-744 PDF Download

SAES-T-744

Design Criteria and Installation of Communication Towers

SAES-T-744 is a standard that establishes the mandatory requirements for the design and installation of steel communication towers, both self-supporting and guyed. The scope of this standard includes various types of antenna towers used for HF (High Frequency), VHF/UHF (Very High Frequency/Ultra High Frequency), microwave, FM/TV broadcasting, and CATV (Cable Television). However, it is important to note that this standard is not applicable to aluminum towers.

The standard provides guidelines and specifications for the design, construction, and installation of steel communication towers. It ensures that the towers are designed to meet the necessary structural requirements, considering factors such as load capacity, wind resistance, and stability. Compliance with this standard helps ensure the safety, reliability, and performance of communication towers in accordance with Saudi Aramco’s regulations.

Industry Codes and Standards for SAES-T-744

The industry code and standard applicable to SAES-T-744 is the TIA/EIA-222-G, which stands for “Structural Standards for Steel Antenna Towers and Antenna Supporting Structures” published by the Electronic Industries Association (EIA).

TIA/EIA-222-G provides comprehensive guidelines and specifications for the structural design, analysis, fabrication, and installation of steel antenna towers and supporting structures. It covers a wide range of communication tower applications, including HF, VHF/UHF, microwave, FM/TV broadcasting, and CATV.

The standard addresses various aspects of tower design, such as loading criteria, structural analysis methods, member design, foundation design, erection procedures, and maintenance considerations. It aims to ensure the safety, stability, and reliability of steel communication towers in compliance with industry standards.

SAES-T-744 references and adopts the TIA/EIA-222-G standard as the authoritative source for the design and installation of steel communication towers within the context of Saudi Aramco’s guidelines and requirements. Adhering to this industry standard helps ensure that communication towers meet the necessary structural integrity and safety criteria.

Design Criteria and Installation of Communication Towers

In accordance with SAES-T-744, the following additional requirements or exceptions are specified for the design of communication towers:

5.1: All aspects of material selection, detailing, shop fabrication, galvanizing, marking for erection, delivery, erection, and assembly of steel structures for communication towers must comply with 12-SAMSS-007.

5.2: Painting and protective coatings for steel structures of the towers should comply with SAES-H-001 and SAES-H-101.

5.3: Communications towers should not incorporate hollow tubular steel members as part of their structure.

5.4: Ice loading should not be considered in the tower loading calculations.

5.5: The County Listing of Minimum Basic Speeds in Section 16 of TIA/EIA-222-G is not applicable. The design basic wind speed for the tower’s location should be determined based on SAES-A-112 and EIA/TIA-222-G. If data is unavailable for a specific location, contact the Environmental Engineering Division. The operational wind speed requirement for tower structures in Saudi Arabia is set at 60 miles per hour.

5.6: The loading capacity of the tower should be calculated to account for the known loading at commissioning and any additional loading expected within one year after commissioning.

5.7: Foundations and concrete used for the tower should comply with 09-SAMSS-097, SAES-Q-001, and SAES-Q-005.

5.8: To prevent corrosion, all anchor rods should be coated with fusion-bonded epoxy. The coating thickness should be 500 to 625 micrometers (20 to 25 mils) as a dry film.

5.9: Guyed towers should not be installed on offshore structures.

5.10: All guyed tower masts for communication sites require separate SSD/1 or SSD/2 security fencing for each guy, unless already included in the perimeter security fence for the tower. Refer to SAES-O-102 for further details.

These additions or exceptions to the TIA/EIA-222-G standard ensure that communication towers in Saudi Arabia meet the specific requirements and considerations of Saudi Aramco.

FAQs about SAES-T-744 PDF Download

Q1: What Standard Should Be Followed For Material Selection, Fabrication, And Assembly Of Communication Towers?

A: All aspects of material selection, detailing, shop fabrication, galvanizing, marking for erection, delivery, erection, and assembly of steel structures for communication towers must comply with 12-SAMSS-007.

Q2: What Are The Requirements For Painting And Protective Coatings On Communication Tower Structures?

A: Painting and protective coatings for steel structures of the towers should comply with SAES-H-001 and SAES-H-101.

Q3: Are Hollow Tubular Steel Members Allowed In Communication Tower Structures?

A: No, communications towers should not incorporate hollow tubular steel members as part of their structure.

Q4: Should Ice Loading Be Considered In Tower Loading Calculations?

A: No, ice loading should not be considered in the tower loading calculations.

Q5: How Should The Design Wind Speed For The Tower Be Determined?

A: The design wind speed for the tower’s location should be determined based on SAES-A-112 and EIA/TIA-222-G. If data is unavailable for a specific location, contact the Environmental Engineering Division. The operational wind speed requirement for tower structures in Saudi Arabia is set at 60 miles per hour.

Q6: How Should The Loading Capacity Of The Tower Be Calculated?

A: The loading capacity of the tower should be calculated to account for the known loading at commissioning and any additional loading expected within one year after commissioning.

Q7: What are the requirements for foundations and concrete used for the tower?

A: Foundations and concrete used for the tower should comply with 09-SAMSS-097, SAES-Q-001, and SAES-Q-005.

Q8: How should anchor rods be protected against corrosion?

A: All anchor rods should be coated with fusion-bonded epoxy to prevent corrosion. The coating thickness should be 500 to 625 micrometers (20 to 25 mils) as a dry film.

Q9: Can guyed towers be installed on offshore structures?

A: No, guyed towers should not be installed on offshore structures.

Q10: What are the requirements for security fencing for guyed tower masts?

A: All guyed tower masts for communication sites require separate SSD/1 or SSD/2 security fencing for each guy, unless already included in the perimeter security fence for the tower. Refer to SAES-O-102 for further details.

Read Also:

SAES-T-928 PDF Download – Telecommunications OSP Buried Plant

SAES-T-920 PDF Download – Telecommunications Cable Information

SAES-T-919 PDF Download – Submarine Fiber Optic Cable

SAES-T-916 PDF Download – Communications Building Cable

SAES-T-914 pDF Download – Communications Distribution Cable

SAES-T-912 PDF Download – Communications Feeder Cable

SAES-T-911 PDF Download – Telecommunication Conduit System Design

SAES-T-906 PDF Download – Telecommunications Structural Coordination

SAES-T-903 PDF Download – Outside Plant Electrical Protection and Grounding

SAES-T-887 PDF Download – Telecommunications: Electrical Coordination Protection at Power Plants and Radio Stations

SAES-T-883 PDF Download – Telecommunications Inductive Coordination

SAES-T-830 PDF Download – Voice Frequency Loop Transmission Objectives

SAES-T-820 PDF Download – Narrow-Band Video Conferencing Systems

SAES-T-795 PDF Download – Communications Facility Grounding Systems

SAES-T-637 PDF Download – Communications Cable Pressure Testing

SAES-T-634 PDF Download – Telecommunications Cable Testing and Acceptance

SAES-T-633 PDF Download – Communications Splice Closures

SAES-T-632 PDF Download – Communications Cable Splicing

SAES-T-631 PDF Download – Communications Cable Terminals

SAES-T-629 PDF Download – Telecommunications Buried Cable and Wire

SAES-T-628 PDF Download – Telecommunications Underground Cable

SAES-T-625 PDF Download – Inter and Intra Building Fiber Optic Communication Cables

SAES-T-624 PDF Download – Telecommunications Outside Plant – Fiber Optics

SAES-T-603 PDF Download – Telecommunications Safeguards and Warning Devices

SAES-T-566 PDF Download – Plant Demilitarized Zone (DMZ) Architecture

SAES-T-556 PDF Download – Circuit Quality and Performance

SAES-T-555 PDF Download – IP Based Closed-Circuit Television (CCTV)

SAES-T-521 PDF Download – Circuit Measuring Techniques

SAES-T-494 PDF Download – Very Small Aperture Terminal (VSAT) Network Design

SAES-T-493 PDF Download – Digital Trunked Radio System

SAES-T-492 PDF Download – VHF/UHF Land-Mobile and Fixed Radio Communication

SAES-T-481 PDF Download – In-Plant Voice Paging System

SAES-T-360 PDF Download – Synchronous Digital Hierarchy Transmission Systems

SAES-T-151 PDF Download – D.C. Power Systems

SAES-T-101 PDF Download – Regulated Vendors List for Communications Equipments and Materials

SAES-T-018 PDF Download – Telecommunications Symbols, Abbreviations and Definitions

SAES-T-000 PDF Download – Telecommunications Standards – Introduction and Indices

Leave a Reply

Your email address will not be published. Required fields are marked *