Table of Contents
| Section | Title | Page |
| Purpose | 2 | |
| Scope | 2 | |
| Related Documents | 2 | |
| Materials | 2 | |
| Attachment Details | 4 | |
| Cold Box Connection Size | 3 | |
| Pressure Tap | 5 | |
| Pressure Tap for Pure Argon | 5 | |
| Instrument Connection With Block and Drain Valve | 6 | |
| Instrument Connection With Block and Double Drain Valves | 6 | |
| Instrument Connection With Block, Drain, and Bleed Valve | 7 | |
| Instrument Connection With Block, Bleed, and Double Drain Valves | 7 | |
| Instrument Connection for Pure Argon | 8 | |
| Instrument Connection for Pure Argon With Drain | 8 | |
| Single Supply Liquid Sample Vaporizer | 9 | |
| Double Supply Liquid Sample Vaporizer | 10 | |
| Local PI With Block and Drain | 11 | |
| Local PI With Block, Drain, and Bleed | 11 | |
| Local PI With Block and Bleed | 12 | |
| Transmitter Mount Double Source | 12 | |
| Transmitter Single Source | 13 | |
| Relief Valve | 13 | |
| Relief Valve With Bleed | 14 | |
| Relief Valve With Bleed for Pure Argon | 14 | |
| Local PI With Block | 15 | |
| Miscellaneous Connection With Block and Drain | 15 | |
| Block and Drain | 16 | |
| Instrument Connection With Block, Drain, Thermal, and Bleed Valve | 16 | |
| Single Supply Liquid Sample Vaporizer With Double Drain | 17 |
1. PURPOSE
1.1 This fabrication and erection specification defines details necessary to fabricate and install field attachments to a cold box.
2. scope
2.1 This specification applies to all cold boxes and circular insulation enclosures (cans).
2.2 Fabrication Scope: All fabrication detailed in this specification shall be the responsibility of the field mechanical contractor unless noted otherwise in the mechanical fabrication specification.
3. related documents
3.1 Air Products Engineering Documents 4WPI-SW70003 Oxygen Clean (Class AA) Inspection and Acceptance Requirements 320010D Liquid Sample Vaporizer
3.2 American Society of Mechanical Engineers (ASME) B16.11 Forged Fittings, Socket-Welding and Threaded B36.19M Stainless Steel Pipe
3.3 American Society for Testing and Materials A 182/A 182M Standard Specification for Forged or Rolled Alloy and Stainless Steel Pipe Flanges, Forged Fittings, and Valves and Parts for High-Temperature Service A 269 Standard Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General Service A 312/A 312M Standard Specification for Seamless, Welded, and Heavily Cold Worked Austenitic Stainless Steel Pipes
4. MATERIALS
4.1 Materials listed in this document are based on ASTM and ASME.
4.2 Any Material or Size Substitutions shall be approved in writing by a representative of Air Products Cold Box Engineering
4.3 All materials shall be oxygen cleaned (Class AA).
4.4 Cold box connection sizes are DN mm (NPS in).
4.5 Maximum pressure rating for components of Table 1 is 99.3 bar g (1440 psig) at -198° to +38°C (‑325° to +100°F). This pressure rating might be further limited by other components (e.g., valves, regulators), piping specifications, and pressure test procedures.
Table 1 Cold Box Connection Size
| PART | COLD BOX CONNECTION SIZE | ||||
| NO. | 15 (1/2″) | 20 (3/4″) | 25 (1″) | 40 (1 ½”) | 50 (2″) |
| 1 | NIPPLE ST STL 15 (1/2″)
SCH 80S SMLS 75 MM (3″) LG TBE ASTM A312 TP304 ASME B36.19M (PNSSA-AJTAE300) |
NIPPLE ST STL 20 (3/4″)
SCH 80S SMLS 75 MM (3″) LG TBE ASTM A312 TP304 ASME B36.19M (PNSSA-AJTAG300) |
NIPPLE ST STL 25 (1″)
SCH 80S SMLS 75 MM (3″) LG TBE ASTM A312 TP304 ASME B36.19M (PNSSA-AJTAI300) |
NIPPLE ST STL 40 (1 ½”)
SCH 80S SMLS 75 MM (3″) LG TBE ASTM A312 TP304 ASME B36.19M (PNSSA-AJTAM300) |
NIPPLE ST STL 50 (2″) SCH 80S SMLS 75 MM (3″) LG TBE ASTM A312
TP 304 ASME B36.19M (PNSSA-AJTAO300) |
| 2 | TEE FGD ST STL15(1/2″)
3000# SCD ASTM A182 GR F304 ASME B16.11 (TESSG-BMENASC) |
TEE FGD ST ST 20 (3/4″)
3000# SCD ASTM A182 GR F304 ASME B16.11 (TESSG BMENASC) |
TEE FGD ST STL 25 (1″) 3000# SCD ASTM A182
GR F304 ASME B16.11 (TESSG-BMENASC) |
TEE FGD ST STL40(1½”) 3000# SCD ASTM 182
GR F304 ASME B16.11 (TESSG BMENASC) |
TEE FGD ST STL 50 (2″) 3000# SCD ASTM A182 GR F304 ASME B16.11 (TESSG-BMENASC) |
| 3 | ELL 90 DEG FGD
ST STL 15 (1/2″) 3000# SCD ASTM A182 GR F304 ASME B16.11 (ELSSG-BM9NNASC) |
ELL 90 DEG FGD
ST STL 20 (3/4″) 3000# SCD ASTM A182 GR F304 ASME B16.11 (ELSSG-BM9NNASC) |
ELL 90 DEG FGD
ST STL 25 (1″) 3000# SCD ASTM A182 GR F304 ASME B16.11 (ELSSG-BM9NNASC) |
ELL 90 DEG FGD
ST STL 40 (1 1/2″) 3000# SCD ASTM A182 GR F304 ASME B16.11 (ELSSG-BM9NNASC) |
ELL 90 DEG FGD
ST STL 50 (2″) 3000# SCD ASTM A182 GR F304 ASME B16.11 (ELSSG-BM9NNASC) |
| 4 | STR ELL 90 DEG FGD
ST STL 15 (1/2″) 3000# SCD ASTM A182 GR F304 ASME B16.11 (ELSSG-BM9NNAST) |
STR ELL 90 DEG FGD
ST STL 20 (3/4″) 3000# SCD ASTM A182 GR F304 ASME B16.11 (ELSSG-BM9NNAST) |
STR ELL 90 DEG FGD ST STL 25 (1″) 3000#
SCD ASTM A182 GR F304 ASME B16.11 (ELSSG-BM9NNAST) |
STR ELL 90 DEG FGD ST STL 40 (1 1/2″) 3000#
SCD ASTM A182 GR F304 ASME B16.11 (ELSSG-BM9NNAST) |
STR ELL 90 DEG FGD ST STL 50 (2″) 3000#
SCD ASTM A182 GR F304 ASME B16.11 (ELSSG-BM9NNAST) |
| 5 | 15 (1/2″) X 8 (1/4″) HEX BUSH FGD ST STL
SCD ASTM A182 GR F304L ASME B16.11 (RESSH-NACACBH) |
||||
| 6 | MALE CONN. ST STL 316 ¼” NPT MALE X ¼” FEM. VCR WITH SILVER PLATED NUT CAJON SS-4-WVCR-1-4 (VCSBD-GSACCS) | ||||
| 7 | GASKET RET. ASSEMBLYUNPLATED NICKEL CAJON NO. NI-4-VCR-2-GR-VS (VCSBF-GGACCS) |
||||
| 8 | MALE CONN. ST STL 316 1/4″ OD TUBE X 1/2″ MALE NPT SWAGELOK SS-400-1-8
(COSAF-SAKICS) |
||||
| 9 | 1/4″ O.D. TUBE ST STL
.035″ WALL SMLS BRIGHT ANNEALED WITH SQUARE CUT ENDS ASTM A269 TP304 (PISAU-JGSSC) |
||||
| 10 | UNION ST STL 316
1/4″ OD TU SWAGELOK SS-400-6 (UNSAF-SMIACS) |
||||
| 11 | LIQUID SAMPLE VAPORIZOR PER ACPI DWG320010D
(MI-320010D) |
||||
| 12 | MALE CONN. ST STL 316 ¼”OD TU X ¼” MALE NPT SWAGELOK
SS-400-1-8 (COSAF-SAIACS) |
||||

Table 1 (continued)
| PART | COLD BOX CONNECTION SIZE | ||||
| NO. | 15 (1/2″) | 20 (3/4″) | 25 (1″) | 40 (1 ½”) | 50 (2″) |
| 13 | TEE FGD ST STL 8 (1/4″) 3000# SCD ASTM A182
GR F304 ASME B16.11 (TESSG-BMENASC) |
||||
| 14 | NIPPLE ST STL 8 (1/4″) SCH 80S SMLS 75 MM
(3″) LG TBE ASTM A312 TP304 ASME B36.19M (PNSSA-AJGAC300) |
||||
| 15 | UNION TEE ST STL 316 1/4″ O.D. TUBE SWAGELOK SS-400-3
(TESAF-SQIACS) |
||||

5. Attachment DETAILS
5.1 The following details provide standard designs for cold box field attachments for: Pressure taps Transmitters Instrument connections Relief valves Sample vaporizers Blocks and drains Local PIs Miscellaneous
Detail F001 Pressure Tap

Detail F002 Pressure Tap for Pure Argon

Detail F003 Instrument Connection With Block and Drain Valve

Detail F004 Instrument Connection With Block and Double Drain Valves

Detail F005 Instrument Connection With Block, Drain, and Bleed Valve

Detail F006 Instrument Connection With Block, Bleed, and Double Drain Valves

Detail F007 Instrument Connection for Pure Argon

Detail F008 Instrument Connection for Pure Argon With Drain

Detail F009 Single Supply Liquid Sample Vaporizer

Detail F010 Double Supply Liquid Sample Vaporizer

Detail F011 Local PI With Block and Drain

Detail F012 Local PI With Block, Drain, and Bleed

Detail F013 Local PI With Block and Bleed

Detail F014 Transmitter Mount Double Source

Detail F015 Transmitter Single Source

Detail F016 Relief valve

Detail F017 Relief Valve With Bleed

Detail F018 Relief Valve With Bleed for Pure Argon

Detail F019 Local PI With Block

Detail F020 Miscellaneous Connection With Block and Drain

Detail F021 Block and Drain

Detail F022 Instrument Connection With Block, Drain, Thermal, and Bleed Valve

Detail F023 Single Supply Liquid Sample Vaporizer With Double Drain