TEST AND INSPECTION PER: EEMUA 146 and Specifications As Noted Below
FITTINGS AND CONNECTOR(OLETS) : COPPER NICKEL ALLOY | INSPECTION & TESTING
Pre-Fabrication/Production Requirements |
Specification Details / Notes: |
Forming Process | |
Material Test Reports | Per EEMUA 146 |
Welding procedure and Procedure qualification and Welding qualification records | Per EEMUA 146 |
NDT Procedures and Personnel | Verify valid personnel qualification and approved procedure |
Fittings -Thickness | From design calculation or Proof (EEMUA 146) |
In process inspection & test requirement |
Specification Details / Notes: |
Heat Treatment | Per EEMUA 146 |
Tensile Test & Hardness test | Per EEMUA 146 |
Chemical Analysis | Per EEMUA 146 |
Weld Seam Liquid penetrant Testing | Per EEMUA 146 |
Weld Seam Radiography Testing | Per EEMUA 146 |
Final inspection & test requirements |
Specification Details / Notes: |
Workmanship, Visual and Dimensional Inspection. | Per EEMUA 146, / Industrial Standard and approved drawings. |
Markings | Per EEMUA 146 |
Protective Coating, End Covers & Packaging | If required |
Additional/Supplemental Requirements |
Specification Details / Notes: |
Other if required | Per PO |