The construction industry has undergone a significant shift from brick masonry to concrete block masonry, owing to the many benefits that concrete blocks offer. These include their fire resistance, good acoustic performance, cost-effectiveness, and strength.
In this article, we will delve into the standard specifications of hollow and solid concrete blocks. These specifications cover a range of factors, such as dimensions, classification, physical requirements, drying shrinkage, moisture movement, water absorption, curing, and drying. By understanding these specifications, builders and construction professionals can ensure that their projects meet the necessary standards and are safe and durable for their intended use.
1. General Specifications
The soundness and quality of both hollow and solid concrete blocks are crucial for their proper placement and overall performance during construction. These blocks must be free from any defects that could compromise their strength or integrity.
Cracks in the blocks can weaken their structure and make them susceptible to damage, while broken edges can hinder their proper placement and alignment during construction. Similarly, honeycombing and other defects can negatively impact the performance and durability of the blocks.
To ensure that the concrete blocks meet the necessary standards for construction, it is essential to carefully inspect them for any imperfections before use. Any blocks that do not meet the required quality standards should be discarded or repaired before being used in construction projects.
By ensuring the soundness and quality of concrete blocks, builders can ensure the structural integrity and durability of their projects. This is especially important in critical applications, such as building foundations, walls, and other load-bearing structures that must withstand heavy loads and adverse weather conditions over time.
Read Also: Rice Husk Ash Concrete Characteristics – Workability, Strength and Admixtures
2. Dimensions and Tolerances
Concrete block units are versatile building materials that come in different sizes and shapes to suit various construction needs. These units include stretcher, corner, double corner or pier, jamb, header, bullnose, partition block, and concrete floor units. To refer to these blocks, their nominal dimensions are used, which include length, height, and width.
The length of concrete blocks is either 400, 500, or 600 mm, while their height can be either 200 or 100 mm. The width of these blocks ranges from 50 to 300 mm, with variations of 75, 100, 150, 200, 250, or 300 mm. To correspond with the full-length blocks, half-length blocks are also manufactured with dimensions of 200, 250, and 300 mm.
The tolerance in the length of these units should not exceed +/- 5 mm, while the maximum variation in height and width should not exceed +/- 3 mm. By following these guidelines, manufacturers can ensure that their concrete blocks meet the required standards for use in construction projects.
3. Classification of Concrete Blocks
The hollow concrete blocks shall be classified in the following four types:
1. Grade ‘A’
Concrete blocks are commonly used as load-bearing units in construction projects. It is important to ensure that these blocks have a minimum density of 1500 kg/m3 to ensure their structural integrity. The manufacturing process of these blocks should also guarantee that they have a minimum compressive strength of 3.5, 4.5, 5.5, and 7.0 N/mm2 after 28 days of curing.
These strength requirements ensure that the blocks can withstand the weight and pressure they will be subjected to during use. By adhering to these standards, builders can ensure that their construction projects are safe, reliable, and meet the necessary building codes.
2. Grade ‘B’
The given context describes the requirements for load-bearing units that are to be manufactured with a block density not less than 1000 kg/m3 and a minimum density of 1500 kg/m3. These load-bearing units are designed to withstand compressive strengths of at least 2.0, 3.0, and 5.0 N/mm2 after 28 days of manufacturing.
It is important that these load-bearing units meet the block density requirement as well as the minimum compressive strength requirements to ensure they can support the intended loads. The specified densities will also provide the necessary stability and durability to ensure the longevity of the load-bearing units.
Manufacturers must ensure that the load-bearing units are manufactured to the specified compressive strengths of 2.0, 3.0, or 5.0 N/mm2 at the end of 28 days. This will ensure that the load-bearing units meet the minimum strength requirements to support the intended loads and are fit for purpose. Overall, adherence to these specifications will ensure that load-bearing units are safe and reliable for their intended use.
3. Grade ‘C’
Concrete blocks are used for various construction purposes and can be categorized based on their grade. Non-load bearing units are a type of concrete block that is not intended to carry any structural load and is therefore designed to have a relatively low density. These blocks must have a block density between 1000 kg/m3 and 1500 kg/m3.
Manufacturers must ensure that non-load bearing concrete blocks have a minimum average compressive strength of 1.5 N/mm2 after 28 days of curing. This requirement ensures that the blocks are sufficiently strong and durable for their intended purpose. By meeting this standard, these blocks can be used effectively in construction projects that require non-load bearing units.
4. Grade ‘D‘
Solid concrete blocks are required to meet a specific density requirement of no less than 1800 kg/m3. Additionally, they must be produced with minimum compressive strengths of 4.0 and 5.0 N/mm2, respectively.
4. Drying Shrinkage
The given context states that the drying shrinkage of blocks, which is the decrease in size or volume of the blocks due to the loss of moisture, should not go beyond 0.1% when there is no restriction applied. The average value of the drying shrinkage of three blocks is considered to determine whether it meets the specified limit.
In other words, the requirement is to ensure that the blocks maintain their size and volume even after they lose moisture during the drying process. If the drying shrinkage exceeds 0.1%, it can indicate poor quality of the blocks and can lead to various issues such as cracking, distortion, or structural instability. Hence, it is essential to monitor and control the drying shrinkage of the blocks to ensure their strength and durability.
5. Compressive Strength and Density
According to the requirements outlined in Table-1, the average compressive strength and density of eight blocks must meet or exceed certain specified values. Specifically, the average compressive strength and density must not fall below the minimum values listed in Table-1. It is important to ensure that these standards are met in order to ensure the quality and durability of the blocks being produced.
Table-1: Compressive Strength and Density of Concrete Blocks
6. Water Absorption
The given context states that the water absorption of three blocks, when averaged, should not exceed 10% of their mass. This means that the total amount of water that the three blocks can absorb should not be more than 10% of their total weight.
Water absorption refers to the ability of a material to absorb water, which can affect its physical properties. In this case, the blocks in question are expected to have a limited ability to absorb water to ensure that they maintain their structural integrity and other desired characteristics.
The requirement for the water absorption limit of the three blocks is crucial in ensuring that they meet the necessary quality standards. It serves as a guideline for the manufacturer to ensure that the blocks are suitable for their intended use and can withstand various environmental conditions. Moreover, the limit can help prevent damage to the blocks due to excessive water absorption, which can be costly to repair or replace.
In conclusion, the context provided emphasizes the importance of controlling water absorption in the production of blocks. This can help ensure that they meet the necessary quality standards and maintain their desired properties, making them suitable for their intended use.
7. Moisture Movement
The given context states that the moisture movement, which is an average value calculated from three different blocks, should not exceed 0.09%. In other words, the maximum allowable moisture movement across the three blocks is 0.09%.
This implies that the moisture content within the blocks should remain stable and not fluctuate beyond this limit, as any significant increase in moisture movement may lead to detrimental effects on the blocks’ structural integrity and performance. Therefore, it is crucial to monitor and control the moisture levels of the blocks to ensure compliance with this requirement.
8. Face Shell and Web Thickness
The thickness of the face shells and webs in concrete blocks should gradually increase from the bottom to the top of the unit. The specific type of core molds used will determine whether the face shells and webs are flared and tapered or straight tapered. It is important to note that the thickness of both the web shell and face shell should meet or exceed the values listed in Table-4 and should not be less than those specified.
Nominal block length and width | Face shell thickness | Thickness of web | Total web thickness per course in any 200 mm of walling |
Min. | Min. | Min. | |
100 or less | 25 | 25 | 25 |
Over 100 to 150 | 25 | 25 | 30 |
Over 150 to 200 | 30 | 25 | 30 |
Over 200 | 35 | 30 | 38 |
9. Curing and Drying
The curing of blocks is an important process that must be carried out either in a curing yard or an immersion tank. Regardless of the method chosen, the blocks must be kept in a moist condition for a period of 14 days. If the immersion tank is used, it is necessary to change the water in it at least once every four days.
After the curing process is complete, the blocks must be dried in the shade before being used for construction. To facilitate the passage of air, the blocks should be stacked with their void-face horizontal. It is essential to ensure that the blocks have completed their initial shrinkage before using them for construction. This will help ensure that the final structure is stable and durable.
10. FAQs about Hollow and Solid Concrete Blocks
-
u003cstrongu003eWhat are the nominal or standard dimensions of the concrete blocks?u003c/strongu003e
Concrete blocks are rectangular building materials that come in various sizes. The nominal dimensions of these blocks include their length, height, and width. The length of these blocks can be 400, 500, or 600 millimeters. Their height, on the other hand, can either be 200 or 100 millimeters. Lastly, the width of concrete blocks can be 50, 75, 100, 150, 200, 250, or 300 millimeters. These variations in dimensions allow builders and contractors to choose the appropriate concrete blocks for their specific building needs.
-
u003cstrongu003eWhat is the allowed tolerance in dimensions of concrete blocks?u003c/strongu003e
The given context states that there are certain limitations to the length, height, and width of the units. According to the guidelines, the maximum variation in the length of the units should not exceed +/- 5 mm, which means that the units cannot be longer or shorter than this specified range. Similarly, the maximum variation in the height and width of the units should not be more than +/- 3mm, indicating that the units should not be higher or wider than this limit.u003cbru003eu003cbru003eThese guidelines are crucial in ensuring that the units meet the required standards and specifications. They ensure that the units are consistent in size, which is essential for their functionality and compatibility with other components. Any variations beyond the specified limits can lead to operational issues, and in extreme cases, they may render the units ineffective.u003cbru003eu003cbru003eTherefore, it is essential to adhere to the prescribed guidelines during the manufacturing and assembly of these units. The production process should be closely monitored to ensure that the units are within the specified dimensions. Any deviations should be immediately corrected to maintain the required standards and quality of the units.
-
u003cstrongu003eWhat are the drying shrinkage, moisture movement, and water absorption limits of concrete blocks?u003c/strongu003e
The specification states that the drying shrinkage of three blocks, when not restrained, should not go beyond 0.1%. This means that the decrease in volume of the blocks due to moisture loss during drying should not exceed 0.1% of their original volume.u003cbru003eu003cbru003eMoreover, the average moisture movement of three blocks should not exceed 0.09%. This refers to the movement of moisture within the blocks, which should be limited to 0.09% of the original volume. This is important to ensure that the blocks remain stable and do not crack or deform due to excessive moisture movement.u003cbru003eu003cbru003eLastly, the water absorption of three blocks should not be more than 10% of their mass. This means that the blocks should not absorb more than 10% of their weight in water. This is significant in ensuring the durability of the blocks, as excessive water absorption can lead to the weakening of the material and subsequent failure.
-
What is standard size of solid concrete block?
The standard size of a solid concrete block is typically 8x8x16 inches (20x20x40 cm).
-
What is solid concrete block compressive strength?
The compressive strength of solid concrete blocks can vary depending on the specific mix design and manufacturing process. However, typical compressive strengths range from 2,500 to 5,000 pounds per square inch (psi) or 17 to 34 megapascals (MPa).
-
What is unit weight of hollow block in kn/m3?
The unit weight of hollow concrete blocks can vary depending on their composition and design. Generally, the unit weight ranges from 1,500 to 2,500 kilograms per cubic meter (94 to 156 pounds per cubic foot) or approximately 15 to 25 kilonewtons per cubic meter (kN/m³).