1. Purpose
American Petroleum Institute (API) 686, Recommended Practices for Machinery Installation and
Installation Design, First Edition, April 1996, is adopted as a SABIC Engineering Standard (SES)
with the following addenda.
2. General
These recommended practices are intended to supplement vendor instructions and the instructions
provided by the original equipment manufacturer (OEM) and shall be followed with regard to
equipment maintenance during storage, installation and checkout.
3. Addenda
The following section, subsection and paragraph numbers refer to API 686, First Edition,
April 1996.
Chapter 2 – Rigging and Lifting
1.2 Preplanning the Lift
1.2.7 The decision is as follows:
The need for manufacturer’s participation shall be determined by SABIC.
Chapter 3 – Jobsite Receiving and Protection
1.1 Scope
1.1.2
Add the following sentence:
Manufacturer shall advise of any preservation requirements that are in addition to API 686, or
provide a statement that the equipment will be adequately protected if API 686 is complied with.
1.3 Preplanning
1.3.3 The decision is as follows:
The need for manufacturer’s participation shall be determined by SABIC.
1.4 Jobsite Receiving and Inspection
1.4.m. Add the following sentence:
Manufacturer shall be contacted if the impact measuring device indicates excessive shock loads or
the equipment appears to be damaged.
1.5 General Instructions – Jobsite Protection
1.5.18. b The decision is as follows:
Measuring of the total acid number (TAN) shall be required.
1.6 Lubricants and Preservatives
1.6.1 Add the following sentence:
Vendor shall advise all proposed preservatives by type, brand and supplier for approval by SABIC
and Manufacturer.
1.10 Compressors – General
1.10.2 Add the following sentence:
Covering shall allow ventilation to prevent moisture accumulation.
1.12 Centrifugal Compressors
1.12.6 The decision is as follows:
If available, nitrogen purge shall be used in all cases.
1.14 Gearboxes
1.14.4 The decision is as follows:
Nitrogen purge shall be used.
1.20 Motors
1.20.2 Storage
1.20.2.7 Add the following sentences:
The motor space heaters shall be placed in operation as soon as the motors are stored and shall
be kept operating continuously. A light bulb shall be installed in parallel with the space heater to
identify whether the heater has been unplugged accidentally. The motor windings shall be
meggered at 2-week intervals. Mechanical inspector shall be contacted if the megger readings are
unsatisfactory.
1.21 Instrumentation on Packaged Machinery
1.21.3 Add the following sentence:
Instrument control panels shall be nitrogen purged during storage.
Chapter 5 – Mounting Plate Grouting
Section 2 – Machinery Grouting Installation Design
2.4 Selection of Grout:
The decision is as follows:
All machinery and associated systems like lube oil system, seal oil system etc shall be grouted with
epoxy grout.
Add the following sentence:
The grout selected for application shall be approved by SABIC.
2.6 Mounting Plate Design
2.6.10 The decision is as follows:
Grouting pins shall be required.
2.7 Grout Design for Auxiliary Equipment
The decision is as follows:
Consoles and other auxiliary equipment skids shall be installed with composite grout pours as
specified in 2.4.2.
Section 3 – Machinery Grouting Installation
3.14 Mounting Plate Grouting
3.14.8 The decision is as follows:
The exposed surface of the grout shall be troweled.
Chapter 6 – Piping
Section 2 – Machinery Piping Installation Design
2.8 Inlet Strainers
2.8.1 Permanent Strainers
The decision is as follows:
Permanent strainers shall not be supplied unless approved by SABIC.
Section 3 – Machinery Specific Piping Installation Design
3.1 Pumps
3.1.2 Pump Suction Piping
3.1.2.6 The decision is as follows:
The pump suction line shall be a minimum straight run of 5 pipe diameters. This dimension can
include the temporary strainer.
Chapter 7- Shaft Alignment
Section 3 – General Requirements
3.1 Installation Data
3.1.3 The decision is as follows:
Ambient offset alignment ideal target readings shall be supplied based on manufacturer’s
estimated equipment growth.
3.2 Format
3.2.1 The decision is as follows:
The checklist and alignment data sheets from this practice shall be used unless SABIC approved
manufacturer’s checklists and alignment data sheets.