This article is about SAES-O-209 which is about Security Doors and download SAES-O-209 PDF for Engineers, supervisors and project managers, QCs, QC Supervisors. This is saudi aramco standards of Safety and Security Engineering based on international codes and standards and useful for Engineering Security knowledge to get job as engineers, QC Supervisors and QC managers, Engineering managers and technicians.
SAES-O-209 PDF Download
SAES-O-209Plant Security Doors
This standard, SAES-O-209, includes essential rules that govern the use of security doors at facilities classified as Class 1, 2, and 3. It is important to follow this standard in conjunction with the Security Directive SEC-09, which is issued by the High Commission for Industrial Security (HCIS) under the Ministry of Interior, Government of Saudi Arabia.
General Requirements:
To ensure the security and safety of Class 1, 2, and 3 facilities that house security systems or serve as process control rooms, this standard, SAES-O-209, outlines mandatory requirements for the doors used in those facilities. It is important to note that the locks for these doors are specified in SAES-O-210. The doors referred to in this standard are categorized as entrance doors, exterior doors, or emergency exit doors.
Definitions:
- Entrance doors: These are doors that lead into areas of the facility where security systems, security control centers, or facility process control rooms are located.
- Exterior doors: These are doors located on the outside of a building that directly open into areas where the facilities or systems mentioned in the entrance door definition are present.
- Emergency exit doors: These are doors intended for emergency evacuation and must comply with the safety standards specified in NFPA 101. Additionally, they should have increased protection against blasts and ballistic threats to maintain the overall security level of the facility.
Requirements:
- Blast Overpressure Resistance: All exterior doors must be designed to withstand blast overpressure based on a building risk assessment study. The design blast pressure should be specified when the predicted blast pressure exceeds a minimum side-on overpressure of 0.5 psi or 1 psi for reflected overpressure (when the door faces the blast source). Blast classifications, such as Low, Moderate, and High, will be used to define door requirements. A survey of typical pressure values for facilities will be conducted in collaboration with other Saudi Aramco departments.
- Vehicle Ramming Prevention: All exterior doors must be equipped with bollards or other barriers to prevent vehicles from ramming into them.
- Emergency Exit Doors: In addition to meeting the safety standards of NFPA 101, emergency exit doors must also provide blast overpressure resistance when opening to the outside.
- Ballistic Protection: All doors, doorframes, and mounting hardware must be certified to comply with the ballistic protection requirements of NIJ-STD-0108.1, level IIIA. The certification should be traceable to an internationally recognized authority.
- Common Requirements: All doors must meet the general requirements stated in Section 4.3 of SEC-09.
Please note that these are simplified explanations of the requirements, and it is essential to refer to the original documents for detailed and complete information.
FAQs about SAES-O-209 PDF
SAES-O-209 categorizes doors into three types: entrance doors, exterior doors, and emergency exit doors.
Exterior doors must be designed to withstand blast overpressure based on a building risk assessment study. The design blast pressure should be specified when the predicted blast pressure exceeds a minimum side-on overpressure of 0.5 psi or 1 psi for reflected overpressure.
Yes, all exterior doors must be equipped with bollards or other barriers to prevent vehicles from ramming into them.
Emergency exit doors must not only comply with the safety standards of NFPA 101 but also provide blast overpressure resistance when opening to the outside.
All doors, doorframes, and mounting hardware must be certified to comply with the ballistic protection requirements of NIJ-STD-0108.1, level IIIA. The certification should be traceable to an internationally recognized authority.