TEST AND INSPECTION PER: ASTM A-179, A-178, A-213, A-210 and Specifications As Noted Below.
TUBES: for Condensers, Tubular Heat-Exchangers, and Similar Heat Transfer Apparatus, Seamless cold-drawn low-carbon steel; 1/8″ to 3″outside diameter.
Pre-Fabrication/Production Requirements |
Specification Details / Notes: |
Material Test Reports | Per applicable ASTM |
Inspection and test plan | Verify manufacturer ITP |
In process inspection & test requirement | Specification Details / Notes: |
Chemical Composition | Per applicable ASTM |
Product Analysis | Positive material Identification(PMI) is required only for ASTM A-213 |
Mechanical Test-Tensile, impact test, Flattering, Flaring, Hardness | Per applicable ASTM. Random witness is required only for Hardness test. |
Hydrostatic Test or NDT unless otherwise specified in P.O. | Per applicable ASTM |
Final inspection & test requirements |
Specification Details / Notes: |
Dimensional Inspection including outside diameter, wall thickness, Length, Squareness of cut ends, number of fins per inch, out of roundness. | Per applicable ASTM and PO requirement. |
Visual Inspection of Completed Tubes | |
Identification Marking , packing and shipment of the Product |
Per ASTM and PO requirement |
Notes:
(1)May only be waived by the responsible Saudi Aramco, ASC, AOC Inspection Offices. (2)See form SA175 – 000003 for instructions on using this form.
(3)Random sampling and witness should performed by the company representative